Apri la demo
Casi / BIM e computo
BIM e computo

Check a model against the EIR and raise issues

Open the information requirements, check a delivered model against them for naming, classification, level of detail and required properties, raise a BCF issue on every gap and sign off only what passes.

4 passaggi11 minConsulente BIM / digitaleSviluppatore / committenteProject e construction management

Come funziona, passo dopo passo

4 passi attraverso la piattaforma - cosa fare a ciascuno e perché conta.

1

Open the requirements

Matrice EIR (ISO 19650)

Open the information requirements the model is meant to satisfy - the naming convention, classification, level of information need and the properties each element must carry.

Perché: You cannot check a model against a standard you have not opened. Starting from the actual requirements turns a vague review into a definite pass or fail on each point.

In entrataInformation requirementsDelivered modelIn uscitaRequirement checklist
2

Check the model against them

Revisione modello

Work through the model checking naming, classification codes, level of detail and the required properties on each element type against the requirement.

Perché: A missing classification or an empty property field breaks the takeoff and the asset handover downstream. Catching it at delivery is far cheaper than finding it when it is needed.

In entrataRequirement checklistIn uscitaFindings against each
3

Raise an issue per gap

Segnalazioni del modello

Raise a BCF issue for every gap against a requirement, pointing at the element and naming what is missing, so the author has a precise list to fix.

Perché: A precise issue gets fixed; a vague complaint that the model is not compliant gets argued. Tying each issue to a requirement and an element removes the room for debate.

In entrataFindingsIn uscitaBCF issues raised
4

Sign off what passes

Matrice EIR (ISO 19650)

Sign off a requirement only once the model actually meets it, so the matrix records true acceptance rather than a hopeful tick.

Perché: Sign-off is the gate that protects everyone downstream. Holding it until the model really complies is what stops a data gap being inherited by the estimator and the operator.

In entrataResolved issuesIn uscitaRequirement signed off

Altro in BIM e computo